Home > ²£«~½u > Cabling-Material(°t½u¾¹§÷) > Fiber_FOT_FTP_¥úÅÖÆl½u_¦¬®e½c_±µÀY_¤¤±µ_¸õ±µ¤Þ½u_¥ú¹qÂà´«¾¹_¾Tºä¾B½ª¹ïµ±½u

Material -- »{ÃѾã¦X¦¡°t½u²£«~ , ±z¥²¶·¨ã¦³ FlashPlayer Æ[¬Ý *.swf °Êµe¼½©ñ¤§³nÅé

¥i¤U¸ü§K¶O¤§¸Õ¥Î³nÅé

  http://www.adobe.com/tw/(¤¤¤å)   http://www.macromedia.com/   (­^¤å)

©Ò¦³¼tµP¤§LOGOª©Åv§¡Âk¸Ó­ì¼t©Ò¦³

¥»³æ¤¸¶È´£¨Ñ¬d¸ß¤§«K§Q©Ê¤Îª¾ÃѤ§¶Ç»¼,½Ð¤Å«IÅvIJªk 

 For Knowledge Only. No Business Prohibited.

¡@

¡@

Fiber..

Fiber¥úÅÖ¦¬®e½c  Rack Mount-¾÷¬[¦¡

proimages/Cabling-Demonstration/fiber-12-24-rack.jpg iber-12-24-rack.jpg

¡@

FIBER RACK MOUNT / FIBER WALL MOUNT  
12¿¶19¦T¾÷¬[¦¡¥úÅÖ¦¬®e½c  24¿¶19¦T¾÷¬[¦¡¥úÅÖ¦¬®e½c  
¯S ¼x:  ¼Ð·Ç19"¾÷¬[¦¡¥úÅÖ¦¬®e½c,¥i¸m©ó19"¾÷Âd±Ä1U³]­p¤£¦ûªÅ¶¡,  ¨ã¦³¦¬®e¤Î³B²z¥úÅÖ¥½ºÝ±µÀY¤§¥\¯à¡C  ³æ¼Ò¤Î¦h¼Ò¥úÅÖ¬Ò¥i¨Ï¥Î,±Ä¥ª±Û±×¶}¦¡©â¨ú«eªO³]­p,©ö©ó¦¬®e¥úÅ֤ΥúÅÖ¥½ºÝ³B²z¡A¬I¤u¤Îºû­×¤è«K ±Ä«á¸m©T©w¾É½u¼Ñ³]­p,§ó©ö©ó©T©w¥úÅÖ·FÆl,¥i¨¾¤î  ¥úÅÖ·FÆl²æ¸¨,©Î¦]¥~¤O·l®`¥úÅÖ·FÆl¤§¿¶½u¡C  ¤Ø¤o( H¡ÑW¡ÑD¤½¤À):4.5¡Ñ43.0¡Ñ28.0
¥i¿ï¥Î¥úÅÖº²±µ½L¸m©ó¨ä¤¤,¦³§Q©ó¥úÅÖº²±µ¬I¤u¡C  ¥i¿ï¥Î¥úÅÖST,SC,FC,FDDI¼Ò²Õ·f°t¨Ï¥Î¡C  (¤£ù׿û¤Î¾T¦Xª÷§÷½è©Î¦h°ð¼Æ¥i±µ¨ü­q»s) 

¡@

¡@

Fiber¥úÅÖ¦¬®e½c  Wall Mount-¾À±¾¦¡

proimages/Cabling-Demonstration/fiber-12-24-wall.jpg fiber-12-24-wall.jpg

12¿¶¾À±¾¦¡¥úÅÖ¦¬®e½c  
24¿¶¾À±¾¦¡¥úÅÖ¦¬®e½c  
¯S ¼x:  12/24¿¶¾À±¾¦¡¥úÅÖ¦¬®e½c±Ä¾À±¾¦¡³]­p,¨ã¦³¦¬®e¤Î  ³B²z¥úÅÖ¥½ºÝ±µÀY¤§¥\¯à¡C  
³æ¼Ò¤Î¦h¼Ò¥úÅÖ¬Ò¥i¨Ï¥Î,¥X½u¤f±Ä±K³¬¦¡³]­p,¥i«O  Å@ADAPTER¤Î¸õ½u¤£¨ü¥~¤O¶Ë®`¡C  ªþÂê.Æ^©óªù¤W.¥H¨¾¤£·í¾Þ§@;Á¡«¬³]­p.
¤Ø¤o  ( H¡ÑW¡ÑD¤½¤À): 25.5¡Ñ26.0¡Ñ6.5,¥i¿ï¥Î¥úÅÖº²  ±µ½L¸m©ó¨ä¤¤¡A¦³§Q©ó¥úÅÖº²±µ¬I¤u¡C  
¥i¿ï¥Î¥úÅÖST,SC,FC,FDDI¼Ò²Õ·f°t¨Ï¥Î¡C  (¤£ù׿û¤Î¾T¦Xª÷§÷½è¥i±µ¨ü­q»s) 

¡@

proimages/Cabling-Demonstration/fiber-36-72-wall.jpg fiber-36-72-wall.jpg

Fiber-Wall-MOUNT--36&72

¡@

¡@

¡@

FC Connector-±µÀY

proimages/Cabling-Demonstration/fiber-fc-connector.jpg fiber-fc-connector.jpg

¥úÅÖ±µÀY(FIBER CONNECTOR)  
³æ¼Ò 9/125£gm --¦h¼Ò 62.5/125£gm-- ST ±µÀY  
¦h¼Ò 62.5/125£gm SC ±µÀY  ³æ¼Ò 9/125£gm FC ±µÀY  ¦h¼Ò 62.5/125£gm FDDI ±µÀY  
¯S ¼x:    ¥Î©ó¥úÆl²×ºÝ¤§³sµ²,¥i¥Î¥úÅÖ±µÀY³s±µ¦Ü¥úÅÖ¿¶½u-±µÀY±Ä¥ÎCeramic³³²¡§÷½è,¤¤¶¡±µÀY±Ä¥ÎBronz¶À»ÉÁáÂ줧§÷½è·¥§C¤§´¡¤J·l¥¢¤Î¦^±Â·l¥¢-- ´£¨Ñ°ªÀW¼e¨Ï¥Î©ó¹q¸Ü³q°T,¹q¸£ºô¸ô,¼v¹³¶Ç¿é--¥úÅ֦ܮୱ(FIBER TO THE DESK),¤Î¦³½u¹qµø¶Ç¿é--¤ä´©Fiber channel 1.062Gbps¤ÎGigabit-Ethernet¶Ç¿é¡C

Pigtail-½Þ§À¦¡¤Þ½u

¡@

proimages/Cabling-Demonstration/fiber-fc-pigtail.jpg fiber-fc-pigtail.jpg

FC-Pigtail

¡@

¡@

Fusion Tray-¥úÅÖ¦¬®e½L

proimages/Cabling-Demonstration/fiber-fusion-tray.jpg fiber-fusion-tray.jpg

Fusion_Tray¥úÅÖº²±µÂI«OÅ@¼öÁY®M  ¥úÅÖ¦¬®e½L§t©T©wªO(12C®e¶q)  ¼öÁY®M©T©wªO(12C®e¶q)

¡@

¡@

LC Connector-±µÀY

proimages/Cabling-Demonstration/fiber-lc-connector.jpg fiber-lc-connector.jpg

LC-connector

¡@

proimages/Cabling-Demonstration/fiber-lc-pigtail.jpg fiber-lc-pigtail.jpg

LC-Pigtail-Duplex

¡@

¡@

Patch Cord-¥úÅÖ¤Þ½u

proimages/Cabling-Demonstration/fiber-lc-sc-duplex-patch-cord.jpg fiber-lc-sc-duplex-patch-cord.jpg

LC-SC-Patch_Cord

¡@

¡@

proimages/Cabling-Demonstration/fiber-lc-sc-pigtail.jpg fiber-lc-sc-pigtail.jpg

LC & SC

¡@

¡@

Fiber Armored Cable-¸Ë¥Ò«¬¥úÅÖÆl½u

¡@

proimages/Cabling-Demonstration/fiber-loose-tube-arnored-outside.jpg fiber-loose-tube-armored-outside.jpg

¡@

À³ ¥Î:  ¥»¥R½¦ª÷ÄÝ¥úÆl¾A¥Î©ó«Ç¤º½u¼Ñ»P«Ç¥~ºÞ¹D¤Îª½®I¥¬©ñ,¥úÆl¤º»Eµ}®ò(³ÍªÜ©ÔKevlar)§Ü±i¤OÅÖºûµ·,¨Ï¥úÆl¯à©Ó¨ü¬I¤u®É¤§À³¤O;¥»µ²ºcÅé«OÅ@¥úÅÖ¤§­@½ÄÀ»»Pªø´ÁÀô¹ÒÅܤƤ§¨Ï¥Î¡C  
¯S ©Ê:  
¥ú ÅÖ³W®æ²Å¦XITU-T G.651¤ÎG.652»PBellcore GR-20-CORE³W½d¡C  ¥úÆl´ú¸Õ¨ÌITU-T G.651,IEC¤Î EIA/TIA-FOTP/492¤ÎANSI-FDDI,  ISO/IEC 11801 °ê»Ú³W½d¡C  ¥úÆl³q¹L¹q«HÁ`§½¥Í²£¯à¤O½Õ¬d¦X®æ¤ÎUL,ISO9002»{ÃÒ¡C  ¥~³QÂÐ(Outer Sheath):»E¤A²m(PE)¶Â¦â¡C  ñZ¸Ë±a(Armor Layer):ª÷ÄÝMetal(Corrugated)¡C  ³ÍªÜ©Ô(Kevlar):»Eµ}®ò¬Á¼þÅÖºûµ·§¡¤Ã¥R¶ñ (Uniformly  distributed Strength Member)¡C  ´²¸m«¬¥úÅÖ(Loose Buffer): ¥HÃC¦â©Î¦L½X¤è¦¡¥H§Q¿ë»{¥úÅÖ¿¶¼Æ¡C  ½w½ÄºÞÃC¦â:³æ¼Ò¬°¶À¦â,¦h¼Ò¬°¾í¦â¡C  ¥úÅÖ«OÅ@¼hÃC¦â:ÂŦâ,¾í¦â,ºñ¦â,´Ä¦â,¦Ç¦â,¥Õ¦â,¬õ¦â,¶Â¦â,¶À¦â,µµ¦â,¯»¬õ¦â,²LÂŦâ¡C

¡@

¡@

¡@

proimages/Cabling-Demonstration/fiber-loose-tube-armored-single-outside-draw.jpg fiber-loose-tube-armored-single-outside-draw.jpg

Single- Tube«Î¥~¥R½¦¸Ë¥Ò«¬¥úÆl(2-12¿¶ )  §¹¦¨¥~®|(Cable O.D.):¡ã9.5mm£X  Ås¦±¥b®|(Bending Radius):  ¹B§@»Ý¡Ù£X¡Ñ10­¿,¬I¤u»Ý¡Ù£X¡Ñ20­¿  ¥úÅÖ·§­«(Cable Weight):¡ã120 KG/KM  ­@À½À£¤O(Crush Resistance):¡Ø3500N/cm(¤û¹y/¤½¤À)  §Ü±i¤O(Loading):¸Ë¸m®É Installation¡Ø3000N(¤û¹y)  ¹B§@®É Long-term¡Ø900N(¤û¹y),²Å¦XEIA/TIA-455 FOTP-332  50/125£gm 4 fiber (Black) 62.5/125£gm 4 fiber (Black) 9/125£gm 4 fiber (Black)

¡@

¡@

proimages/Cabling-Demonstration/fiber-loose-tube-armored-multi-outside-draw.jpg fiber-loose-tube-armored-multi-outside-draw.jpg

Multi- Tube«Î¥~¥R½¦ª÷Äݸ˥ҫ¬¥úÆl(12-48¿¶ )  ¥úÅÖºØÃþ(Fiber Type): ¥úÅÖ·§­«(Cable Weight):¡ã220 KG/KM  ³æ¼Ò(SMF:9/125) (12-48¿¶) ­@À½À£¤O(Crush Resistance):¡Ø3500N/cm(¤û¹y/¤½¤À)  ¦h¼Ò(MMF:50/125,62.5/125) (12-48¿¶) §Ü±i¤O(Loading):  §¹¦¨¥~®|(Cable O.D.):¡ã12.5mm£X ¸Ë¸m®É Installation¡Ø3000N(¤û¹y)  Ås¦±¥b®|(Bending Radius): ¹B§@®É Long-term¡Ø900N(¤û¹y)  ¹B§@»Ý¡Ù£X¡Ñ10­¿,¬I¤u»Ý¡Ù£X¡Ñ20­¿ ²Å¦XEIA/TIA-455 FOTP-332 

¡@

¡@

Fiber Outside Cable-«Î¥~«¬¥úÅÖÆl½u

proimages/Cabling-Demonstration/fiber-loose-tube-outside.jpg fiber-loose-tube-outside.jpg

§C·ÏµL¬r¨¾¹««r¬°­q»s«~,¥B²Å¦X
IEC 332-1,IEC 332-3/3C,IEC  754/745-1,UL1685/FT4,UL 94V¡C  ³ÍªÜ©Ô(Kevlar):»Eµ}®ò¬Á¼þÅÖºûµ·§¡¤Ã¶ñ¥R (Uniformly  distributed Strength Member-Aramid Yarn)¡C  ´²¸m«¬½w½ÄºÞ¥úÅÖ(Loose Buffer):¥H¦â½X¿ë»{¥úÅÖ¿¶¼Æ¡C  ½w½ÄºÞÃC¦â:³æ¼Ò¶À¦â ¦h¼Ò¾í¦â¡C  ¥úÅÖ«OÅ@¼hÃC¦â:ÂŦâ,¾í¦â,ºñ¦â,´Ä¦â,¦Ç¦â,¥Õ¦â,¬õ¦â,¶Â¦â,¶À  ¦â,µµ¦â,¯»¬õ¦â,²LÂŦâ¡C 

´²¸m«¬½w½ÄºÞ «Dª÷ÄÝ ³æ½w½ÄºÞ/¦h½w½ÄºÞ¥»¥R½¦¨¾¤ô«Dª÷Äݨ¾¹««r¨¾¹pÀ»¥úÆl¾A¥Î©ó«Ç¤º½u¼Ñ»P«Ç¥~ºÞ¹D  
§G©ñµL¶·±µ¦a,¥úÆl¤º»Eµ}®ò(³ÍªÜ©ÔKevlar)§Ü±i¤OÅÖºûµ·,¨Ï¥ú  Æl¦b¬I¤u®É¯à©Ó¨üªºÀ³¤O;¸Óµ²ºc«OÃÒ¥úÅÖªº§Ü½ÄÀ»©Ê»P¹ïÀô¹Ò  ªø´ÁÅܤƪº¾AÀ³©Ê¡C  
¯S ©Ê:  ¥úÅÖ³W®æ²Å¦XITU-T G.651¤ÎG.652»PBellcore GR-20-CORE³W½d¡C  ¥úÅÖ´ú¸Õ¨ÌITU-T G.651,IEC¤ÎEIA/TIA-FOTP/492¤ÎANSI-FDDI,  ISO/IEC 11801°ê»Ú³W½d¡C  ¥úÆl³q¹L¹q«HÁ`§½¥Í²£¯à¤O½Õ¬d¦X®æ¤ÎUL,ISO9002»{ÃÒ¡C  ¥~¥Ö(Outer Sheath):»E¤A²m(HDPE or MDPE)¶Â¦â,¥B²Å¦XIEC-502,  IEC-1034,IEC-708,ASTM-D1248¡C

¡@

¡@

proimages/Cabling-Demonstration/fiber-loose-tube-single-outside-draw.jpg fiber-loose-tube-single-outside-draw.jpg

Single- Tube«Î¥~¥R½¦«Dª÷ÄÝ¥úÆl(2-12¿¶)  §¹¦¨¥~®|(Cable O.D.):9.5¡ã10mm£X  Ås¦±¥b®|(Bending Radius):¹B§@»Ý¡Ù£X¡Ñ10,¬I¤u»Ý¡Ù£X¡Ñ20­¿  ¥úÅÖ·§­«(Cable Weight):¡ã120 KG/KM  ­@À½À£¤O(Crush Resistance):¡Ø3500N/cm(¤û¹y/¤½¤À)  §Ü±i¤O(Loading)²Å¦XEIA/TIA-455 FOTP-33¤§¼Ð·Ç:¸Ë¸m®É  Installation¡Ø3000N(¤û¹y) ¹B§@®ÉLong-term¡Ø900N(¤û¹y)  §Ü½ÄÀ»¤O¡Ø3500N/CM ««ª½§G©ñ°ª«×¡Ø150M  µ±¦Xªø«×¡Ø125¡Ñ£X(CABLE O.D.) ½ÄÀ»Â\Àú´ú¸Õ¡Ø3000 CYCLES  ¹B§@·Å«×: -40¢J¡ã+80¢J Àx¦s·Å«×: -50¢J¡ã+80¢J 

¡@

¡@

proimages/Cabling-Demonstration/fiber-loose-tube-multi-outside-draw.jpg fiber-loose-tube-multi-outside-draw.jpg

Multi- Tube«Î¥~¥R½¦«Dª÷ÄÝ¥úÆl(12-96¿¶)  ¥úÅÖºØÃþ(Fiber Type): ­@À½À£¤O(Crush Resistance):¡Ø3500N/cm(¤û¹y/¤½¤À)  ³æ¼Ò(SMF:8.3¡ã9.5/125) (12-96¿¶) §Ü±i¤O(Loading)²Å¦XEIA/TIA-455 FOTP-33¤§¼Ð·Ç:¸Ë¸m®É  ¦h¼Ò(MMF:50/125,62.5/125) (12-96¿¶) Installation¡Ø3000N(¤û¹y¡^¹B§@®ÉLong-term¡Ø900N(¤û¹y)  §¹¦¨¥~®|(Cable O.D.):10-12.5mm£X §Ü½ÄÀ»¤O¡Ø3500N/CM ««ª½¥¬©ñ°ª«×¡Ø150M  Ås¦±¥b®|(Bending Radius) : µ±¦Xªø«×¡Ø125¡Ñ£XD(CABLE O.D.)  ¹B§@»Ý¡Ù£X¡Ñ10­¿,¬I¤u»Ý¡Ù£X¡Ñ20­¿ ½ÄÀ»Â\Àú´ú¸Õ¡Ø3000 CYCLES  ¥úÅÖ·§­«(Cable Weight):¡ã220 KG/KM ¹B§@·Å«×: -40¢J¡ã+80¢J ,Àx¦s·Å«×: -50¢J¡ã+80¢J 

¡@

¡@

¡@

proimages/Cabling-Demonstration/fiber-mtrj-pigtail.jpg fiber-mtrj-pigtail.jpg

ADAPTORS:(Bronze)  
³æ¼Ò 9/125£gm ST-- ¦h¼Ò 62.5/125£gm --¤¤¶¡±µÀY  ¦h¼Ò 62.5/125£gm SC ¤¤¶¡±µÀY  
³æ¼Ò 9/125£gm FC ¤¤¶¡±µÀY  
¦h¼Ò 62.5/125£gm FDDI ¤¤¶¡±µÀY  
¦h¼Ò ST-SC ¤¤¶¡±µÀY (æX¾¹)  
¦h¼Ò ST-FC ¤¤¶¡±µÀY (æX¾¹)  
¦h¼Ò ST-FDDI ¤¤¶¡±µÀY (æX¾¹)  
¦h¼Ò MTRJ-MTRJ ¤¤¶¡±µÀY (æX¾¹)  
³æ ¼Ò´¡¤J·l¥¢Typical Insertion Loss:< 0.1dB  ¦h¼Ò´¡¤J·l¥¢Typical Insertion Loss:< 0.3dB  ¹B§@·Å«×Operating Temperature: -40 ¢J¡ã+85¢J  ¶J¦s·Å«×Storage Temperature: -55 ¢J¡ã+85¢J  ¸Ë¸m·Å«×Install Temperature: -40¢J¡ã+85¢J 

¡@

¡@

¡@

proimages/Cabling-Demonstration/fiber-sc-adaptor.jpg fiber-sc-adaptor.jpg

¡@

 

¡@

¡@

proimages/Cabling-Demonstration/fiber-sc-connector.jpg fiber-sc-connector.jpg

SC-Connector

¡@

proimages/Cabling-Demonstration/fiber-sc-duplex-pigtail.jpg fiber-sc-duplex-pigtail.jpg

SC-Duplex

¡@

¡@

¡@

proimages/Cabling-Demonstration/fiber-sc-mtrj-pigtail.jpg fiber-sc-mtrj-pigtail.jpg

¡@

[1]-SC
[2]-MTRJ

¡@

¡@

proimages/Cabling-Demonstration/fiber-sc-pigtail.jpg fiber-sc-pigtail.jpg

SC

¡@

¡@

¡@

¡@

Adaptor-¤¤¶¡±µÀY(½¢¦X¾¹)

 

proimages/Cabling-Demonstration/fiber-st-mtrj-adaptor.jpg fiber-st-mtrj-adaptor.jpg

[Left]-MTRJ-Adaptor
[Right]-ST-Adaptor

¡@

¡@

¡@

proimages/Cabling-Demonstration/fiber-sc-sc-patch-cord.jpg fiber-sc-sc-patch-cord.jpg

¡@

¡@

proimages/Cabling-Demonstration/fiber-sc-simplex-pigtail.jpg fiber-sc-simplex-pigtail.jpg

¡@

¡@

proimages/Cabling-Demonstration/fiber-st-connector.jpg fiber-st-connector.jpg

 

¡@

¡@

¡@

¡@

¡@

¡@

proimages/Cabling-Demonstration/fiber-st-pigtail.jpg fiber-st-pigtail.jpg

¡@

¡@

proimages/Cabling-Demonstration/fiber-st-st-patch-cord.jpg fiber-st-st-patch-cord.jpg

³æ¼Ò (9/125)-¦h¼Ò (50/125)-¦h¼Ò (62.5/125£gm) FC 1¦Ì½Þ§À¦¡¤Þ½u  
¦h¼Ò (62.5/125£gm) MTRJ-MTRJ 3¦ÌÂù¿¶¤Þ½u  
¦h¼Ò (62.5/125£gm) MTRJ-SC 3¦ÌÂù¿¶¤Þ½u  
¦h¼Ò (62.5/125£gm) MTRJ-ST 3¦ÌÂù¿¶¤Þ½u  * ¦UºØ±µÀY«¬¦¡.¥úÅÖ¼ÒºA¤Îªø«×¬Ò¥i­q»s 

¡@

¥úÅÖ¤Þ½u(FIBER PATCH CORD)  
³æ¼Ò (9/125)-¦h¼Ò (50/125)-¦h¼Ò (62.5/125£gm) ST-ST 3¦ÌÂù¿¶¤Þ½u  
³æ¼Ò (9/125)-¦h¼Ò (50/125)-¦h¼Ò (62.5/125£gm) SC-SC 3¦ÌÂù¿¶¤Þ½u  
³æ¼Ò (9/125)-¦h¼Ò (50/125)-¦h¼Ò (62.5/125£gm) FC-FC 3¦ÌÂù¿¶¤Þ½u  
¦h¼Ò (62.5/125£gm) FDDI-FDDI 3¦ÌÂù¿¶¤Þ½u  
¦h¼Ò (62.5/125£gm) ST-FDDI 3¦ÌÂù¿¶¤Þ½u  
¦h¼Ò (62.5/125£gm) SC-FDDI 3¦ÌÂù¿¶¤Þ½u  
³æ¼Ò (9/125)-¦h¼Ò (50/125)-¦h¼Ò (62.5/125£gm) ST-SC 3¦ÌÂù¿¶¤Þ½u  
³æ¼Ò (9/125)-¦h¼Ò (50/125)-¦h¼Ò (62.5/125£gm) ST 1¦Ì½Þ§À¦¡¤Þ½u  
³æ¼Ò (9/125)-¦h¼Ò (50/125)-¦h¼Ò (62.5/125£gm) SC 1¦Ì½Þ§À¦¡¤Þ½u 

¡@

proimages/Cabling-Demonstration/fiber-st-st-pigtail-red-black.jpg fiber-st-st-pigtail-red-black.jpg

¯S ¼x:  ¥Î©ó¥úÆl²×ºÝ¤§³sµ²,¥i¥Î¥úÅÖ¤Þ½u³s±µ¦Ü¥úÅÖ³]³ÆºÝ¡C±µÀY±Ä¥ÎCeramic³³²¡§÷½è,·¥§C¤§´¡¤J·l¥¢¤Î¦^±Â·l¥¢¡C´£¨Ñ°ªÀW¼e¨Ï¥Î©ó¹q¸Ü³q°T,¹q¸£ºô¸ô, ¼v¹³¶Ç¿é,¥úÅ֦ܮୱ  (FIBER TO THE DESK), ¤Î¦³½u¹qµø¶Ç¿é¡C  ¤ä´©Fiber channel 1.062Gbps¤Î Gigabit-Ethernet¶Ç¿é¡C  
³W ®æ:  ³æ¼Ò09/125£gm,¦h¼Ò50/125£gm,¦h¼Ò62.5/125£gm¡C  ±µÀY«¬¦¡ST,SC,FC,FDDI,BICONIC,D4,DIN,SMA...MTRJ¡C

¼Ð ·Ç: ²Å¦X¤U¦C´ú¸Õ³W½d­n¨D  ISO/IEC 11801,EN5O173,UL,approved  ITU-T G.651,G.652, ISO9002 Certified  EIA/TIA 568A/FOTP-455 (ANSI X3T9.5 PMD)  GR-NWT-000326(GR-326-CORE).ICEA-83-596  
¹q®ð¯S©Ê:  
´¡¤J·l¥¢Typical Insertion ³æ¼Ò< 0.15dB ¦h¼Ò< 0.3dB  
³Ì¤j´¡¤J·l¥¢Max.Insertion ³æ¼Ò< 0.25dB ¦h¼Ò< 0.4dB  
¦^±Â·l¥¢Typical Return ³æ¼Ò> -50dB ¦h¼Ò> -62dB  
³Ì¤j¦^±Â·l¥¢Max. Return ³æ¼Ò> -48dB ¦h¼Ò> -60dB  
¹B§@·Å«×Operating Temperature:-40¢J¡ã+75¢J  
¶J¦s·Å«×Storage Temperature:-55¢J¡ã+85¢J  
¸Ë¸m·Å«×Install Temperature:-40¢J¡ã+85¢J 

¡@

¡@

¡@

Fiber Tight-Buffer Cable-§ôºò«¬¥úÅÖÆl½u

proimages/Cabling-Demonstration/fiber-tight-buffer-distribution.jpg fiber-tight-buffer-distribution.jpg

§ôºò«¬Distribution ¤À§G«¬¥úÆl
(4-36¿¶)§ôºò«¬½w½ÄºÞ¥úÅÖ(Tight Buffer):  900£gm¥HÃC¦â©Î¦L½X¤è¦¡¥H§Q¿ë»{¥úÅÖ¿¶¼Æ  ¥úÅÖºØÃþ(Fiber Type):  
³æ¼Ò(SMF:9/125) (4-36¿¶)  
--¦h¼Ò(MMF:50/125,62.5/125) (4-36¿¶)  
§¹ ¦¨¥~®|(Cable O.D.):5-15mm£X  ¹B§@Ås¦±¥b®|(Bending Radius): ¸Ë¸m®É>£X¡Ñ10­¿  ¥úÅÖ·§­«(Cable Weight):20-160 KG/KM  ¬I¤u©Ô¤O(Pulling Force):¡Ø1000N(¤û¹y)  ¥[±j¥]¸Ë§ôºò«¬¥úÅÖ(Tight Buffer Simplex):  2.0,2.4,3.0mm  ¥HÃC¦â©Î¦L½X¤è¦¡¥H§Q¿ë»{¥úÅÖ¿¶¼Æ

¡@

proimages/Cabling-Demonstration/fiber-tight-buffer-distribution-draw.jpg fiber-tight-buffer-distribution-draw.jpg

[1]-±j¤Æ²Õ´¶ñ¥R(S.M.)
[2]-§ôºò«¬¥úÅÖ(Tight Buffer)
[3]-¤¤¤ß§Ü±iÅé(C.S.M)
[4]-³ÍªÜ©Ô¥]¸Ë(Kevlar)
[5]-¥~¥Ö(Outer Sheath)

À³ ¥Î:  À³¥Î©ó«Ç¤º¼Ó¼h»P¼Ó¼h(««ª½)©Î³æ¼h¼Ó­±(¤ô¥­)¥úÅÖ§G©ñ¡C¥iª½±µ»P¥úÅÖ±µÀY²Õ¦¨§ÀÅ֩θõ½u,¥HÁYµu²{³õ³sµ²¬I¤u©Ò¥Îªº®É¶¡¡C  
¯S ©Ê:  
¥úÅÖ³W®æ²Å¦XITU-T G.651¤ÎG.652°ê»Ú³W½d»PBellcore GR-409-CORE³W½d¡C  ¥úÆl´ú¸Õ¨ÌITU-T G.651¤ÎG.652,IEC¤ÎEIA/TIA-FOTP¤ÎANSI-FDDI ISO/IEC 11801°ê»Ú³W½d¡C  
¥~ ¥Ö(Outer Sheath):±Ä¥Î»E´â¤A²m(PVC) ³æ¼Ò¬°¶À¦â,¦h¼Ò¬°¾í¦â¡C  ³ÍªÜ©Ô(Kevlar):»Eµ}®ò¬Á¼þÅÖºûµ·§¡¤Ã¥R¶ñ (Uniformly distrib-uted Strength Member)¡C  ¤¤¤ß§Ü±iÅé(C.S.M):µwÀ½«¬¬Á¼þÅÖºûFRP (Central Strength Member)¡C  ¥úÅÖ«OÅ@¼hÃC¦â:ÂŦâ,¾í¦â,ºñ¦â,´Ä¦â,¦Ç¦â,¥Õ¦â,¬õ¦â,¶Â¦â,¶À¦â,µµ¦â,¯»¬õ¦â,²LÂŦâ¡C  ¥úÆl³q¹L¹q«HÁ`§½¥Í²£¯à¤O½Õ¬d¦X®æ¤ÎUL,ISO9002»{ÃÒ,¨Ã²Å¦XUL »P OFNR ­@¤õ¯S©Ê¡C

¡@

¡@

Fiber Fan-Out Cable-¥[­«§ôºò«¬¥úÅÖÆl½u

proimages/Cabling-Demonstration/fiber-tight-buffer-fan-out.jpg fiber-tight-buffer-fan-out.jpg

§¹ ¦¨¥~®|(Cable O.D.):8.5-21mm£X  ¹B§@Ås¦±¥b®|(Bending Radius):¸Ë¸m®É>£X¡Ñ10­¿  ¥úÅÖ·§­«(Cable Weight):75-430 KG/KM  ¬I¤u©Ô¤O(Pulling Force):¡Ø3500N(¤û¹y)  ««ª½¤W¤É°ª«×(Vertical Height):

¡@

proimages/Cabling-Demonstration/fiber-tight-buffer-fan-out-draw.jpg fiber-tight-buffer-fan-out-draw.jpg

[1]-¥~¥Ö(Outer Sheath)
[2]-§ôºò«¬¥úÅÖ(Tight Buffer)
[3]-¤¤¤ß§Ü±iÅé(C.S.M)
[4]-¥[±j¥]¸Ë§ôºò«¬¥úÅÖ(Simplex)
[5]-³ÍªÜ©Ô¥[±j²Õ´(Kevlar S.M.)

¡@

 

¡@

¡@

¡@

FOT-¥ú¹q¶Ç¿é¾¹

proimages/Cabling-Demonstration/fot-1st-4-in-1.jpg fot-1st-4-in-1.jpg

²£ «~¯S¦â:¤¹³\¦hºØ¤A¤Óºô¸ô¤¶­±¼Ð·Ç 10 Base-2/5/T/FL ¦P®É¤À§G¦b¬J¦¨¤§ºô¸ô¤¤¡C  ¥|¦X¤@¤¶­± 1ST ¶Ç¿é¾¹10Mbps  10 Base-FL ¬O°ê»Ú¹q¾÷¹q¤l¤uµ{¨ó·| IEEE 802.3 ¤A¤Óºô¸ô¥úÅּзÇ,¨Ï¥Î¥»¤½¥q¥|¦X¤@¤¶­±1ST¦h¼Ò¥úÅֶǿ龹,¨Ïºô¸ô¨t²Î¼W¯q¦Ü³Ì·s¼Ð·Ç¡C  ¦¹¤@¦h¼Ò¥úÅֶǿ龹,±N«D±`²³æ±q¤w¦s¦bªºµL¾B½ªÂùµ±½uºô¸ô(UTP)¤Î²ÓÆlºô¸ô(BNC)¤Î²ÊÆlºô¸ô(AUI)Âà´«¦¨¥úÅÖºô¸ô(ST¤@²Õ)¨Ïºô¸ô¥d©Î¶° ½u¾¹ªº¶Ç¿é¯à§¹¥þ²Å¦X¥úÅֶǿé¼Ò¦¡¦b¥úÅÖÆl½u¤W,¹F¨ì2¤½¨½¡C  

² ³æ©ö©ó¾Þ§@ªº¤G¬q¦ì¸m·Æ°Ê¶}Ãö,¥i¿ï¾Ü³s±µ¤u§@¯¸¥x(WORKSTATION)©Î¤¤¼Ï¶°½u¾¹(HUB)¨Ï¥ÎµL¾B½ªÂùµ±½u¸õ±µ½u,±N¤£¦A¦]³s±µ¤u§@¯¸©Î¤¤¼Ï ¶°½u¾¹¥²¶·§ó´«¤£¦Pªº¸õ±µ½u¤§³Â·Ð¤Î¿ù»~,»Ý¨Ï¥ÎÂI¹ïÂI¤è¦¡§Y¥i,¦hºØ«ü¥Ü¿OÅã¥Ü¦p POWER ,LMON ,COL ,JAB ,XMT ,RCV, AUI,BNC,LINK,TPRCV§ó©ö©óÀ˭פκô¸ô¨t²ÎºûÅ@¡C  
±µ ¤f:RJ-45 ¥À®y±µÀY for 10 Base-T  ¤@²ÕST ¥úÅÖ±µÀY for 10 Base-FL  BNC ¥À®y±µÀY for 10 Base-2  DB-15 ¥À®y±µÀY for 10 Base-5  
Æl ½uºØÃþ:²Ä5 ÃþµL¾B½ªÂùµ±½u for 10 Base-T  ¦h¼Ò¥úÅÖ 62.5/125um for 10 Base-FL  RG-58 ¦P¶b¹qÆl for 10 Base-2  AUI DROP CABLE for 10 Base-5¤¶­±  Æl½uªø«×:µL¾B½ªÂùµ±½u,³Ìªø100¦Ì for 10 Base-T  ¦h¼Ò¥úÅÖ 62.5/125um,³Ìªø2¤½¨½  for 10 Base-FL  RG-58 ¦P¶b¹qÆl,³Ìªø185¦Ì for 10 Base-2  
AUI DROP CABLE,³Ìªø50¦Ì for 10 Base-5  
«ü¥Ü¿OÅã¥Ü:POWER ,LMON ,COL ,JAB ,XMT ,RCV,LINK  AUI,BNC,TPTX  
·Å «×:0¢J to 55¢J (¾Þ§@¼Ð·Ç)  
Àã «×:10 to 90% (non-condensing)  
¼Ð ·Ç:IEEE 802.3 10 Base-2  10 Bsae-5  10 Base-T  10 Base-FL¤A¤Óºô¸ô¼Ð·Ç  
¶Ç¿é«¬ºA:°òÀW  ¹qºÏ¤zÂZ:²Å¦X FCC Class A Subpart B  of Part 15  ¥~Æ[¤Ø¤o:4.22"(¼e)*5.89"(ªø)*1.05"(°ª)  
¹q·½Âà´«¾¹:¥~±µ¦¡SWITCHING¹q·½  
³s±µ¶}Ãö³]©w: ¤G¬q¦ì¸m·Æ°Ê¶}Ãö³]©w
(HUB or W/S) for  Thin Coaxial 50 ohm Terminator 

¡@

¡@

¡@

proimages/Cabling-Demonstration/fot-4st-4-in-1.jpg fot-4st-4-in-1.jpg

¥|¦X¤@¤¶­± 4ST ¶Ç¿é¾¹10Mbps  10 Base-FL ¬O°ê»Ú¹q¾÷¹q¤l¤uµ{¨ó·| IEEE802.3¤A¤Óºô¸ô
¥úÅּзÇ,¨Ï¥Î¥»¤½¥q¥|¦X¤@¤¶­±4ST¦h¼Ò¥úÅֶǿ龹,¨Ïºô¸ô¨t²Î¼W¯q¦Ü³Ì·s¼Ð·Ç¡C  ¦¹¤@¦h¼Ò¥úÅֶǿ龹,±N«D±`²³æ±q¤w¦s¦bªºµL¾B½ªÂùµ±½uºô¸ô(UTP)¤Î²ÓÆlºô¸ô(BNC)¤Î²ÊÆlºô¸ô(AUI)Âà´«¦¨¥úÅÖºô¸ô(ST ¥|²Õ)¨Ïºô¸ô¥d©Î¶°½u¾¹ªº¶Ç¿é
¯à §¹¥þ²Å¦X¥úÅֶǿé¼Ò¦¡¦b¥úÅÖÆl½u¤W,¹F¨ì2¤½¨½¡C  ²³æ©ö©ó¾Þ§@ªº¤G¬q¦ì¸m·Æ°Ê¶}Ãö,¥i¿ï¾Ü³s±µ¤u§@¯¸¥x(WORKSTATION)©Î¤¤¼Ï¶°½u¾¹(HUB)¨Ï¥ÎµL¾B½ªÂùµ±½u¸õ±µ½u,±N¤£¦A¦]³s±µ¤u§@¯¸©Î¤¤ ¼Ï¶°½u¾¹¥²¶·§ó´«¤£¦Pªº¸õ±µ½u¤§³Â·Ð¤Î¿ù»~,»Ý¨Ï¥ÎÂI���ÂI¤è¦¡§Y¥i,¦hºØ«ü¥Ü¿OÅã¥Ü¦pPOWER ,LMON ,COL ,JAB ,XMT ,RCV ,AUI ,BNC ,LINK ,TPRCV §ó©ö©óÀ˭פκô¸ô¨t²ÎºûÅ@¡C  
²£«~¯S¦â:  ¤¹³\¦hºØ¤A¤Óºô¸ô¤¶­±¼Ð·Ç 10 Base-2/5/T/FL ¦P®É¤À§G¦b¬J¦¨¤§ºô¸ô¤¤¡C 

±µ ¤f:RJ-45 ¥À®y±µÀY for 10 Base-T  ¥|²ÕST ¥úÅÖ±µÀY for 10 Base-FL  BNC ¥À®y±µÀY for 10 Base-2  DB-15 ¥À®y±µÀY for 10 Base-5  
Æl ½uºØÃþ:²Ä5 ÃþµL¾B½ªÂùµ±½u for 10 Base-T  ¦h¼Ò¥úÅÖ 62.5/125um for 10 Base-FL  RG-58 ¦P¶b¹qÆl for 10 Base-2  AUI DROP CABLE for 10 Base-5¤¶­±  Æl½uªø«×:µL¾B½ªÂùµ±½u,³Ìªø100¦Ì for 10 Base-T  ¦h¼Ò¥úÅÖ 62.5/125um,³Ìªø2¤½¨½  for 10 Base-FL  RG-58 ¦P¶b¹qÆl,³Ìªø185¦Ì for 10 Base-2  AUI DROP CABLE,³Ìªø50¦Ì for 10 Base-5  
«ü¥Ü¿OÅã¥Ü:POWER ,LMON ,COL ,JAB ,XMT ,RCV,LINK  AUI,BNC,TPTX  
·Å «×:0¢J to 55¢J (¾Þ§@¼Ð·Ç)
Àã «×:10 to 90% (non-condensing)  
¼Ð ·Ç:IEEE 802.3 10 Base-2  10 Bsae-5  10 Base-T  10 Base-FL¤A¤Óºô¸ô¼Ð·Ç  
¶Ç¿é«¬ºA:°òÀW  ¹qºÏ¤zÂZ:²Å¦X FCC Class A Subpart B  of Part 15  ¥~Æ[¤Ø¤o:8.34"(¼e)*6.5"(ªø)*1.05"(°ª)  
¹q·½Âà´«¾¹:  ¥~±µSWITCHING¹q·½ AC115V/3A AC230V/1.5A  
³s±µ¶}Ãö³]©w:  ¤G¬q¦ì¸m·Æ°Ê¶}Ãö³]©w(HUB or W/S) for  Thin Coaxial 50 ohm Terminator

¡@

 

¡@

¡@

proimages/Cabling-Demonstration/fot-st-utp-10.jpg fot-st-utp-10.jpg

UTP ÂàST¥úÅֶǿ龹10Mbps  10 Base-FL ¬O°ê»Ú¹q¾÷¹q¤l¤uµ{¨ó·| IEEE 802.3 ¤A¤Óºô¸ô¥úÅÖ¼Ð·Ç ,¨Ï¥Î¥»¤½¥q¶WÁ¡«¬¦h¼Ò¥úÅֶǿ龹 ,¨Ïºô¸ô¨t²Î¼W¯q¦Ü³Ì·s¼Ð·Ç¡C  ¦¹¤@¦h¼Ò¥úÅֶǿ龹,±N«D±`²³æ±q¤w¦s¦bªºµL¾B½ªÂùµ±½uºô¸ô (UTP) Âà´«¦¨ ¥úÅÖºô¸ô (ST) ¨Ïºô¸ô¥d©Î¶°½u¾¹ªº¶Ç¿é¯à§¹¥þ²Å¦X¥úÅֶǿé¼Ò¦¡¦b¥úÅÖÆl½u¤W,¹F¨ì2¤½¨½¡C  ²³æ©ö©ó¾Þ§@ªº¤G¬q¦ì¸m·Æ°Ê¶}Ãö,¥i¿ï¾Ü³s±µ¤u§@¯¸¥x(WORKSTATION)©Î¤¤¼Ï¶°½u¾¹(HUB)

¨Ï ¥ÎµL¾B½ªÂùµ±½u¸õ±µ½u,±N¤£¦A¦]³s±µ¤u§@¯¸©Î¤¤¼Ï¶°½u¾¹¥²¶·§ó´«¤£¦Pªº¸õ±µ½u¤§³Â·Ð¤Î¿ù»~,¬é»Ý¨Ï¥ÎÂI¹ïÂI¤è¦¡§Y¥i,¦hºØ«ü¥Ü¿OÅã¥Ü¦p POWER ,LMON ,COL ,JAB ,XMT ,RCV§ó©ö©óÀ˭פκô¸ô¨t²ÎºûÅ@¡C  ±µ ¤f:RJ-45 ¥À®y±µÀY for 10 Base-T  ST ¥úÅÖ±µÀY for 10 Base-FL  Æl½uºØÃþ:²Ä3,4or5 ÃþµL¾B½ªÂùµ±½u for 10 Base-T  ¦h¼Ò¥úÅÖ 62.5/125um for 10 Base-FL ¤¶­±  Æl½uªø«×:µL¾B½ªÂùµ±½u,³Ìªø100¦Ì  ¦h¼Ò¥úÅÖ 62.5/125um,³Ìªø2¤½¨½  
«ü¥Ü¿OÅã¥Ü:POWER ,LMON ,COL ,JAB ,XMT ,RCV,LINK
·Å «×:0¢J to 55¢J (¾Þ§@¼Ð·Ç)  Àã «×:10 to 90% (non-condensing)  
¼Ð ·Ç:IEEE 802.3 10 Base-T/FL¤A¤Óºô¸ô  ¿é«¬ºA:°òÀW  
¹qºÏ¤zÂZ:  ²Å¦X FCC Class A Subpart B of Part 15  
¥~Æ[¤Ø¤o:2.2"(¼e)¡Ñ4.2"(ªø)¡Ñ0.8"(°ª)

¡@

¡@

¡@

¡@

proimages/Cabling-Demonstration/fot-st-utp-100.jpg fot-st-utp-100.jpg

UTPÂàST¥úÅֶǿ龹100Mbps  100 Base-FL ¬O°ê»Ú¹q¾÷¹q¤l¤uµ{¨ó·| IEEE 802.3 ¤A¤Óºô¸ô¥úÅÖ
¼Ð ·Ç ,¨Ï¥Î¥»¤½¥q¶WÁ¡«¬¦h¼Ò¥úÅֶǿ龹 ,¨Ïºô¸ô¨t²Î¼W¯q¦Ü³Ì·s¼Ð·Ç¡C  ¦¹¤@¦h¼Ò¥úÅֶǿ龹,±N«D±`²³æ±q¤w¦s¦bªºµL¾B½ªÂùµ±½uºô¸ô (UTP) Âà´«¦¨ ¥úÅÖºô¸ô (ST) ¨Ïºô¸ô¥d©Î¶°½u¾¹ªº¶Ç¿é¯à§¹¥þ²Å¦X¥úÅֶǿé¼Ò¦¡¦b¥úÅÖÆl½u¤W,¹F¨ì2¤½¨½¡C  ²³æ©ö©ó¾Þ§@ªº¤G¬q¦ì¸m·Æ°Ê¶}Ãö,¥i¿ï¾Ü³s±µ¤u§@¯¸¥x(WORKSTATION)©Î¤¤¼Ï¶°½u¾¹(HUB)

¨Ï ¥ÎµL¾B½ªÂùµ±½u¸õ±µ½u,±N¤£¦A¦]³s±µ¤u§@¯¸©Î¤¤¼Ï¶°½u¾¹¥²¶·§ó´«¤£¦Pªº¸õ±µ½u¤§³Â·Ð¤Î¿ù»~,»Ý¨Ï¥ÎÂI¹ïÂI¤è¦¡§Y¥i,¦hºØ«ü¥Ü¿OÅã¥Ü¦p POWER ,LMON ,COL ,JAB ,XMT ,RCV §ó©ö©óÀ˭פκô¸ô¨t²ÎºûÅ@¡C¦¹¤@±jªi¶Ç¿é¾¹,±N«D±`²³æ±q¤w¦s¦bªºµL¾B½ª¹ïµ±
ºô¸ô (UTP)¹ï(UTP)¨Ïºô¸ô¶Ç¿é¯à§¹¥þ²Å¦X¤A¤Óºô¸ô¶Ç¿é¼Ò¦¡±NµL¾B½ª¹ïµ±½u°T¸¹±jªi,
¹F¨ì100¤½¤Ø¡C ¬Y¨Ç¹q¸£¾÷ºØ«á­±¤¶­±´¡¼ÑªÅ¶¡«D±`¯U¤p,¥»¤½¥q¶WÁ¡«¬¶Ç¿é¾¹§Y°w¹ï
¦¹¦Ó³]­p,¦p SUN SPARC,IBMRS/6000,  or APPLE MACINTOSH¡C  
¦hºØ«ü¥Ü¿OÅã¥Ü¦p POWER , HUB-LINK ,
W/S-LINK , HUB  -COL , W/S-COL , HUB-RCX
, W/S-RCX ,§ó©ö©óÀ˭פκô  µ¸¨t²ÎºûÅ@¡C 

¡@

¡@

¡@

FOT-¥ú¹q¶Ç¿é¾¹

¡@

¡@

proimages/Cabling-Demonstration/fot-utp-sc-100-3cnet.jpg fot-utp-sc-100-3cnet.jpg

¡@

FOT-SC-UTP-100mbps

±µ ¤f:RJ-45 ¥À®y±µÀY for 100 Base-T  ST ¥úÅÖ±µÀY for 100 Base-FL  Æl½uºØÃþ:²Ä¤­ÃþµL¾B½ª¹ïµ±½u for 100 Base-T  ¦h¼Ò¥úÅÖ 62.5/125um for 100 Base-FL ±µ¤f  Æl½uªø«×:µL¾B½ªÂùµ±½u,³Ìªø100¦Ì  ¦h¼Ò¥úÅÖ 62.5/125um,³Ìªø2¤½¨½  
«ü¥Ü¿OÅã¥Ü:POWER ,LMON ,COL ,JAB ,XMT ,RCV,LINK  
·Å «×:0¢J to 55¢J (¾Þ§@¼Ð·Ç)  
Àã «×:10 to 90% (non-condensing)  
¼Ð ·Ç:IEEE 802.3 100 Base-T/FL¤A¤Óºô¸ô¼Ð·Ç  
¶Ç¿é«¬ºA:°òÀW  ¹qºÏ¤zÂZ:  ²Å¦X FCC Class A Subpart B of Part 15  ¥~Æ[¤Ø¤o:2.2"(¼e)¡Ñ4.2"(ªø)¡Ñ0.8"(°ª)

¡@

¡@

¡@

¡@

proimages/Cabling-Demonstration/fot-utp-sc-100-3cnet-power-supply.jpg fot-utp-sc-100-3cnet-power-supply.jpg

¡@

¡@

proimages/Cabling-Demonstration/fot-utp-sc-100-3cnet-set.jpg fot-utp-sc-100-3cnet-set.jpg

¡@

¡@

¡@

FOT-Application ¥ú¹q¶Ç¿é¾¹À³¥Î

proimages/Cabling-Demonstration/fot-utp-sc-100-application.jpg fot-utp-sc-100-application.jpg

¡@

proimages/Cabling-Demonstration/fot-utp-sc-100-remote.jpg fot-utp-sc-100-remote.jpg

¡@

¡@

¡@

¡@

FTP-¾T¾B½ª¹ïµ±¹qÆl

proimages/Cabling-Demonstration/ftp-cat-5e-004-gray.jpg ftp-cat-5e-004-gray.jpg

CAT.5 Enhanced FTP CABLE  
¶W¤­µ¥¯Å ¥|¹ï¦¡ ¾T¾B½ª¹ïµ±¹qÆl³W ®æ:¾ÉÅ鬰 ¥|¹ï(4 PAIR)24AWG ³æ¿¶»É¾É½uºc¦¨¡C
¥]¸Ë±Ä¥Î¯È½c¸Ë,305M(1000Ft)/½c,©ö©ó·h¹B¡C
¾É½uµ´½t±Ä¥ÎFRPE,HDPE¶ì½¦§÷½è¡CÆl½u¥~³QÂбĥÎFR-PVC(­@¿UPVC),¦Ç¦â¡C
Æl½u¥~®|:5.6¡Ó0.3mm,¥i­q»sLSZH§C·ÏµL¬r³W®æ¡C

¡@

¡@

proimages/Cabling-Demonstration/ftp-cat-5e-004-draw.jpg ftp-cat-5e-004-draw.jpg

[1]-­é¥Ö¤Þ½u Ripcord
[2]-¾T¾B½ª Mylar Foil
[3]-µ´½tInsulation
[4]-»É¾ÉÅé Conductor
[5]-¥~¥ÖJacket

¡@

 

proimages/Cabling-Demonstration/sftp-cat-5e-strain-gray.jpg  sftp-cat-5e-strain-gray.jpg

¡@

proimages/Cabling-Demonstration/ftp-cat-5e-004-strain-draw.jpg ftp-cat-5e-004-strain-draw.jpg

[1]-­é¥Ö¤Þ½u Ripcord
[2]-¾T¾B½ª Mylar Foil
[3]-µ´½tInsulation
[4]-»É¾ÉÅé Conductor[¤C¿¶³nµ±½u32awg*7=24awg ]
[5]-¥~¥ÖJacket

¡@